High Boiler Pressure? How to Bring It Down Safely
Is the needle on your boiler’s pressure gauge up in the red, or has the boiler shut down with a high-pressure fault? This usually happens after the system has been topped up a little too much, or when a filling valve hasn’t been closed fully. In many cases you can bring the pressure back down safely yourself by bleeding a radiator, exactly as the boiler manufacturers describe. Here’s how, and when it’s a job for an engineer instead. Never take the cover off a boiler, and never touch the pressure relief valve or any gas part.
What counts as too high?
Worcester Bosch says that with the heating system cool, the gauge should read between 1 and 1.5 bar, and that a reading of about 2.75 bar or more (the red section) means the pressure is too high. It’s normal for the reading to rise a little while the heating is running. Baxi notes that if the pressure gets too high, the pressure relief valve may open and you may see water dripping from a small copper pipe, usually outside. Some boilers also show an error code, so check your user manual for your model.
Why does boiler pressure go up?
- The system was overfilled when it was last topped up.
- The filling loop or filling key wasn’t closed fully, so water keeps creeping in from the mains.
- A fault inside the system, such as an expansion vessel that needs attention. Worcester Bosch says that if the pressure rises by more than 1 bar when the heating is up to temperature, the expansion vessel may need repressurising by an engineer.
How to bring high boiler pressure down safely
- Switch the heating off and let everything cool. Radiator water can be very hot, so wait until the radiators are cool enough to touch.
- Check the filling controls are fully closed. Using your boiler’s user manual to identify them, make sure the filling loop valves (or the filling key or lever) are fully shut. Don’t force anything.
- Get ready to bleed a radiator. You’ll need a radiator key (or a flat screwdriver for some modern radiators), an old towel and a small container to catch the water.
- Open the bleed valve slowly. Holding the cloth under the valve at the top of the radiator, turn the key a little anticlockwise. Let out any air and a small amount of water, then close the valve again. Don’t unscrew the valve completely.
- Go back and check the gauge. If it’s still above the green zone, let out a little more water and check again. Small steps are best, so you don’t take it too low.
- Stop at 1 to 1.5 bar with the system cold (or the figure in your manual). If you overshoot and it drops below 1 bar, follow our guide to topping up low boiler pressure, then close the filling controls fully.
- Restart the boiler. If it’s showing a fault, use the reset button once if your manual says you can. Keep an eye on the gauge over the next few days.
What not to do
- Don’t open, adjust or test the pressure relief valve, and don’t block or cut the small pipe that runs from it to the outside wall.
- Don’t bleed radiators while the heating is hot, and don’t try to drain the system yourself.
- Don’t remove the boiler casing or any panel, or touch gas valves, burners, the expansion vessel or the flue. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on gas appliances.
- Don’t keep pressing the reset button if the boiler locks out again.
When to stop and call us
- The pressure keeps creeping back up even though the filling controls are closed. That can point to a filling valve or expansion vessel fault, which needs an engineer.
- The pressure jumps by more than about 1 bar each time the heating warms up.
- Water is dripping or running from the pipe on the outside wall, or from the boiler itself.
- The bleed valve won’t close, is damaged, or keeps leaking.
- You can’t confidently identify the filling controls on your boiler.
- The boiler locks out again after one reset.
Our Gas Safe registered engineers carry out boiler repairs across Clare, Sudbury and the surrounding area, and an annual boiler service is a good time to have the expansion vessel and pressure checked. If your boiler is showing a code you don’t recognise, our guide to boiler fault codes explains what to check first.
Safety first
Smell gas or suspect carbon monoxide? Leave the property, open doors and windows if it’s safe, don’t use light switches or naked flames, turn the gas off at the meter only if it’s safe to do so, and call the National Gas Emergency Service on 0800 111 999. Get medical advice if anyone has CO symptoms such as headaches, dizziness, nausea or tiredness. You can check that an engineer is registered on the Gas Safe Register.
Never touch electrics near water. If a breaker trips, you may reset it once from a dry spot; if it trips again, leave it off and call a registered (Part P) electrician. If water is leaking heavily, turn off the inside stopcock first (here’s how to find your stopcock). The outside or boundary stop tap is usually owned by your water company (Anglian Water or Essex & Suffolk Water) and may need a special key, so don’t dig it up or force it. Contact your water company about a leak on their side, and check whether neighbours are affected.
Sources and further reading
- Worcester Bosch: how often should I top up the pressure?
- Baxi: how to fix high boiler pressure
- Viessmann: what to do if your boiler pressure is too high
- Gas Safe Register
- Your boiler manufacturer’s user manual, which always takes priority for your model.