Toilet Keeps Running? How to Stop It and When to Call a Plumber

If your toilet keeps running after you flush, with a constant trickle down the back of the pan or a cistern that hisses and refills every few minutes, the cause is almost always inside the cistern: a flush button that hasn’t popped back up, a worn flush valve seal, or a fill valve that isn’t shutting off. You can usually stop the water in a minute by closing the small isolation valve on the pipe feeding the toilet. If you’re in Clare, Sudbury, Haverhill, Long Melford or a village nearby, here’s what to check safely, and when to hand it over to us.

Why a running toilet is worth sorting quickly

A trickle into the pan looks harmless, but it runs day and night. On a water meter you pay for every litre, and Anglian Water’s leakage leaflet lists a leaking loo as one of the first things to check when a bill or meter reading looks too high. A running toilet isn’t usually an emergency, though. If the water is going into the pan and nothing is overflowing onto the floor, it can normally wait for a booked visit.

Is it really running? The tissue test

Sometimes the leak is so slow you can’t hear it. Anglian Water suggests this simple check:

  1. Make sure the flush button isn’t stuck down, and don’t flush the toilet for about 30 minutes.
  2. Dry the back of the bowl with a piece of toilet tissue (don’t flush it).
  3. Lay a fresh, dry sheet of tissue across the back of the bowl.
  4. Come back in a few hours. If the paper is wet or torn, water is seeping from the cistern into the pan.

Step by step: how to stop a toilet that keeps running

  1. Check the flush button first. Press it once and let go. Dual-flush buttons, especially the push-button types on modern toilets, can stick part way down and hold the valve open. If it springs back and the running stops, that was the problem. If it keeps sticking, note it for the plumber rather than forcing it or prising it out.
  2. Find the isolation valve. It’s a small valve on the pipe going into the cistern, usually low down behind or beside the toilet. It has a screwdriver slot or a little lever. As Which? Trusted Traders explains, closing it stops water going into the cistern.
  3. Turn it a quarter turn. When the slot or lever sits across the pipe, the valve is closed. Turn it gently with a flat-head screwdriver or a coin. If it won’t move easily, don’t force it, as old valves can snap or start leaking.
  4. Listen. Once the cistern has finished emptying into the pan, the running should stop. If it carries on, the water is coming from somewhere else, so go to the next step.
  5. No isolation valve, or it won’t turn? Turn off your inside stopcock instead. Our guide on how to find and turn off your stopcock shows the usual places to look. If the stopcock won’t move either, see our guide to a seized or leaking stopcock rather than using grips on it.
  6. Using the toilet in the meantime. With the valve closed the cistern won’t refill. You can still flush by opening the valve, letting the cistern fill, then closing it again after you flush. Some people simply fill the cistern from a jug through the open lid instead.
  7. Look, but don’t fiddle. If you can lift the cistern lid easily (not a concealed cistern behind a panel), take a quick photo of the parts inside. Check whether the water level is right up at the overflow pipe in the middle or at the side. That photo helps us bring the right part first time.
  8. Check outside and on the floor. Some older toilets have an overflow pipe through the outside wall. If yours is dripping there (rather than quietly into the pan), see our guide to a dripping toilet overflow. Wipe up any water on the bathroom floor, keep it away from any electric shower, shaver socket or heater, and don’t touch electrics with wet hands.

Avoid these mistakes

  • Don’t bend the float arm, wedge the float, or tie anything inside the cistern to stop it. It can stop the cistern refilling properly or make it overflow.
  • Don’t take the flush valve or fill valve apart with the water still on, and don’t remove a concealed cistern’s wall panel or tiles to get to it. Concealed cisterns usually need the right access and parts.
  • Don’t fit replacement parts you’re not sure about. Under the Water Supply (Water Fittings) Regulations 1999, toilet valves and cisterns must be suitable for the job and must not waste or contaminate water, so the fitting has to be the right type for your toilet and water pressure.
  • Don’t use chemical cleaners or bleach tablets as a “fix”. They won’t seal a worn valve and can make the rubber parts perish faster.
  • If water has got near sockets or a light, don’t touch them. You may reset a tripped RCD or circuit breaker once if your hands and the floor are completely dry; if it trips again, leave it off and call a registered (Part P) electrician.

When to stop and call us

  • The toilet is still running after you’ve checked the button, or the tissue test shows a leak. A worn flush valve seal or fill valve is a quick job for our toilet repair team.
  • The isolation valve is missing, stuck or dripping. We can fit a new one so you can shut the toilet off on its own in future. Our plumbing page covers the rest of what we do.
  • It’s a concealed cistern, a wall-hung toilet or a push-button flush you can’t get at.
  • Water is coming out of the cistern, round the base of the pan or through the ceiling below. Turn off your stopcock and call our emergency plumbing team. Our guide to a flood or burst pipe covers what to do while you wait.
  • Your water meter keeps turning even with the toilet isolated. There may be another leak, and our guide to using a water meter to find a leak or our leak detection service can track it down.

The outside or boundary stop tap is usually owned by your water company (Anglian Water or Essex & Suffolk Water) and may need a special key, so don’t dig it up or force it. If you think there’s a leak on their side, check whether neighbours are affected and contact the water company.

Smell gas or suspect carbon monoxide? Leave the property, open doors and windows if it’s safe, don’t use light switches or naked flames, turn the gas off at the meter only if it’s safe to do so, and call the National Gas Emergency Service on 0800 111 999. Get medical advice if anyone has CO symptoms such as headaches, dizziness or nausea. Only a Gas Safe registered engineer may work on gas appliances; you can check an engineer on the Gas Safe Register.

Sources and further reading

Toilet still running? Call Anglian PHE.

Call 01787 278511 or call/WhatsApp 07825 348536 (message us on WhatsApp). With over 10 local engineers, we’ll attend as soon as possible, even at midnight. No call-out fee.

Anglian PHE Ltd, Top Floor, 4 Market Hill, Clare, Sudbury CO10 8NN. Gas Safe 572792, NAPIT registered, trading since 1993.

This is general safety guidance. If you’re unsure, stop and call a qualified engineer.