Heating Won’t Come On? Timer and Thermostat Checks to Try First

Cold radiators on the first chilly evening of the year? Before you book a repair, it’s worth spending five minutes on the controls. A surprising number of “broken” heating systems turn out to be a thermostat set below room temperature, a timer that lost its settings in a power cut, or a radiator valve someone closed over the summer. Ideal Heating lists exactly these as problems a householder can check. Here’s a simple order to work through. Every step below uses only the controls on the outside of your boiler, programmer and thermostat. Please don’t take any covers or casings off.

First, which problem do you have?

  • Hot water works, but the heating won’t come on. The boiler is running, so the cause is usually the timer, the thermostat, heating mode or the radiator valves. Start with the checks below.
  • No heating and no hot water. Check power and the boiler display first (steps 1 and 2), then see our no hot water quick checks.
  • The boiler shows a fault code or a red light. Write the code down and look it up in your user manual. Our boiler fault codes guide explains what to note.
  • Some radiators heat but others don’t. That’s usually air, sludge or balancing rather than the controls. See how to bleed a radiator and radiator cold at the bottom.

Timer and thermostat checks, step by step

  1. Check the boiler has power. Is the display lit? Look at the switch or fused spur on the wall next to the boiler and make sure it’s on. If the lights in the house are off, it may be a power cut, and if you have a prepayment meter, check it has credit.
  2. Check the consumer unit once. If one breaker is in a different position to the others, it may have tripped. You can reset it once, standing somewhere dry. If it trips again, leave it off and call a registered electrician. Don’t keep flicking it back on.
  3. Check the clock on the programmer. After a power cut, many timers reset to midnight or flash. If the clock is wrong, your heating may be trying to run at 3am instead of 6pm. Set the correct time using the buttons, as your programmer’s instructions describe.
  4. Check the heating programme and mode. Make sure the heating channel isn’t set to “off” or “hot water only”, and that the on periods cover now. Many boilers also have a summer/winter or heating on/off button; check heating is switched on. Try the “advance”, “boost” or “+1 hour” button to see if the heating fires up straight away.
  5. Turn the room thermostat up. Your heating will never come on if the thermostat is set lower than the room temperature. Turn it up to about 20°C, as Ideal suggests, and listen for a click or watch the boiler display for the heating symbol. A wireless thermostat may simply need fresh batteries; follow the maker’s instructions for changing them.
  6. Check a smart thermostat or app. If you use one, look for a holiday mode, frost-only mode or a schedule that was changed. Check the hub has power and the app shows it as online.
  7. Turn the radiator valves up. If radiators were turned off over summer, open the thermostatic valves by hand to a middle setting, such as 3. A TRV that won’t turn shouldn’t be forced.
  8. Check the boiler pressure. On a combi or sealed system, a gauge below about 1 bar can stop the boiler working. Top it up only as your user manual describes. Our guide to low boiler pressure walks you through it.
  9. In freezing weather, check the condensate pipe. If it’s below zero and the boiler shows a fault, the small plastic pipe outside may have frozen. Thaw it with warm, not boiling, water. See frozen condensate pipe.
  10. Reset once, if your manual allows. If the boiler has locked out, press the reset button once as the user manual describes, then give it a few minutes. If it locks out again, stop and call a Gas Safe engineer.

What not to do

  • Don’t remove the cover of the thermostat, programmer, wiring centre or wall switch, and don’t touch the wiring. Electrical faults in heating controls need a registered (Part P) electrician or a heating engineer.
  • Don’t take the boiler casing off or touch the gas valve, burner, fan or flue. Under the Gas Safety (Installation and Use) Regulations 1998, only a Gas Safe registered engineer may work on gas appliances.
  • Don’t keep pressing the reset button or keep topping up the pressure. A reset isn’t a repair, and repeated lockouts or pressure loss mean something needs diagnosing.
  • Don’t use an old portable gas or paraffin heater indoors as a stopgap, and never block air vents to keep warm.

When to stop and call us

  • The controls are all set correctly, the boiler has power and pressure, and the heating still won’t come on.
  • The boiler locks out again after one reset, or shows the same fault code repeatedly.
  • You keep having to top up the pressure. Our guide to boiler pressure that keeps dropping explains why.
  • The thermostat or programmer is blank even with fresh batteries and power on, or a breaker trips again.
  • The boiler makes unusual noises, or you see soot, staining or a lazy yellow flame. Stop using it and call a Gas Safe engineer.

Our Gas Safe engineers carry out boiler repairs across Clare, Sudbury and the surrounding area, and an annual boiler service before winter can pick up worn parts early. Faulty heating controls or wiring can be checked by our electricians.

Safety first

Smell gas or suspect carbon monoxide? Leave the property, open doors and windows if it’s safe, don’t use light switches or naked flames, turn the gas off at the meter only if it’s safe to do so, and call the National Gas Emergency Service on 0800 111 999. Get medical advice if anyone has CO symptoms such as headaches, dizziness, nausea or tiredness. You can check that an engineer is registered on the Gas Safe Register.

Never touch electrics near water. If a breaker trips, you may reset it once from a dry spot; if it trips again, leave it off and call a registered (Part P) electrician. If you find a water leak, turn off the inside stopcock first; here’s how to find your stopcock. The outside or boundary stop tap is usually owned by your water company (Anglian Water or Essex & Suffolk Water) and may need a special key, so don’t dig it up or force it. Contact your water company about a leak on their side, and check whether neighbours are affected too. Our guide to the outside stop tap explains more.

Sources and further reading

Heating still won’t come on? Call Anglian PHE.

Call 01787 278511 or WhatsApp 07825 348536. With over 10 local engineers, we’ll attend as soon as possible, even at midnight. No call-out fee.

Anglian PHE Ltd, Top Floor, 4 Market Hill, Clare, Sudbury CO10 8NN. Gas Safe 572792, NAPIT registered, trading since 1993.

This is general safety guidance. If you’re unsure, stop and call a qualified engineer.

Similar Posts